Sunday, January 22, 2023

How to connect PLC and HMI in TIA Portal?

 

Description
This post will give you a guide to the topics of connection between:

  • WinCC Runtime Advanced and S7 controller via Industrial Ethernet (PROFINET)
  • SIMATIC HMI Panel and S7 controller via Industrial Ethernet (PROFINET) 


Connection between WinCC Runtime Advanced and S7 controller 

Requirements

  • WinCC (TIA Portal) Advanced
  • STEP 7 (TIA Portal) Basic/Professional (depending on the controller used)
  • PC with PROFINET/Ethernet interface
  • S7 controller with PROFINET/Ethernet interface

Instructions

  1. Create a new project in the TIA Portal.
  2. In the Project View you double-click "Add new device" and select the S7 controller. Click the "OK" button to add the controller.

    Note
    Depending on the selected CPU, the dialog "PLC Security settings" is automatically displayed. Parameterize the security settings according to the requirements of your plant. You may cancel the dialog and configure the settings in the CPU at later time via Properties > General > Protection & Security.
    Through the Hardware Catalog you can add more components to the Device View (like power supply, IO modules).


    Fig. 01


  3. Click the PROFINET interface of the S7 controller and assign a unique IP address and the associated subnet mask under "Properties > General > Ethernet Addresses".


  4. Fig. 02


  5. Double-click "Add new device" and select WinCC Runtime Advanced.


    Fig. 03


  6. In the Device View in the Hardware Catalog you select the "IE General" communication module and double-click to add this to the PC station.


    Fig. 04


  7. Click the "IE General" interface just added. Under "Properties > General > PROFINET interface [X1] > Ethernet Addresses" you enter the IP address and subnet mask of the Runtime Station.


    Fig. 05


  8. Switch to the Devices & Network view and enable "Connections" to create an HMI connection.
    Connect the interfaces of the S7 controller and the Runtime station by drag-and-drop.


    Fig. 06



    Fig. 07


  9. Click the HMI connection. Under "Properties > General >" you enter the name you are using in the PG/PC interface of the Runtime station. In this example we use the preset name "S7ONLINE".


    Fig. 08


  10. Open the PG/PC interface on the Runtime station via "Start > Control Panel > Set PG/PC interface.


    Fig. 09


  11.  
  12. Under Access Point of the Application, select the access point that was also set under point 8. In this example we use the preset name "S7ONLINE". 
    Under "Interface Parameter Assignment Used:" you select the "TCP/IP Ethernet Adapter" you are using.

    Select the entry of your interface with the extension ".TCPIP.1". If set correctly, the entire entry in the example is "Intel(R) 82574L Gigabit Network Connection.TCPIP.1".




    Fig. 10


  13. Complete the configuration and download the project to the S7 controller and the Runtime station.



Connection between SIMATIC HMI Panel and S7 controller

Requirements

  • WinCC (TIA Portal) Basic/Comfort (depending on the panel used)
  • STEP 7 (TIA Portal) Basic/Professional (depending on the controller used)
  • SIMATIC HMI Panel with PROFINET/Ethernet interface
    Make sure that the operator panel you select can communicate with the desired controller. This information is in the technical data of the device.
  • S7 controller with PROFINET/Ethernet interface

Instructions

  1. Create a new project in the TIA Portal.
  2. In the Project View you double-click "Add new device" and select the S7 controller. Click the "OK" button to add the controller.

    Note
    Depending on the selected CPU, the dialog "PLC Security settings" is automatically displayed. Parameterize the security settings according to the requirements of your plant. You may cancel the dialog and configure the settings in the CPU at later time via Properties > General > Protection & Security.
    Through the Hardware Catalog you can add more components to the Device View (like power supply, IO modules).


    Fig. 11


  3. Click the PROFINET interface of the controller and assign a unique IP address and the associated subnet mask under "Properties > General > Ethernet Addresses".


    Fig. 12


  4. Double-click "Add new device" and select the HMI panel. Place a check mark for "Start device wizard" and click the OK button.


    Fig. 13

     
  5. In the "HMI Device Wizard" dialog that opens, click "Browse" and select the CPU with which you want to establish a PLC connection.


    Fig. 14


    Fig. 15


  6. The connection parameters are entered and the next free IP address is automatically reserved for the HMI panel. Close the HMI wizard by clicking the "Finish" button.


  7. Fig. 16

       
  8. Complete the configuration and download the project to the S7 controller and the HMI panel.

Learn more about SIMATIC STEP 7 - TIA Portal Projec "Ready-for-use“ for SIWAREX WP321

Ready-for-use TIA Portal 

TIA Portal example project for S7-1500
(S7-1511 and KTP700 Basic or MTP700 Unified Comfort) in German, English, French, Spanish and Italian consisting of HMI visualization and WP321 function block (multiinstance ability).

7MH4138-6AA00-0BA0 

SIWAREX WP321 WEIGHING ELECTRONIC (1 CHANNEL) FOR STRAIN GAUGE LOAD CELLS / FULL BRIDGES (1-4 mV/V) FOR SIMATIC ET200SP, FITS to BU-TYPE A0, RS485- INTERFACE FOR CONNECTION OF SIWATOOL OR A REMOTE DISPLAY Detailed load cell diagnostics possible with digital junction box SIWAREX DB (7MH5001-0AD20 or 7MH5001-0AD0

 

The .zip-file includes the following components:

  • TIA Portal V15.1, V16, V17 and V18 project with SIWAREX WP321 – KTP 700 Basic
  • TIA Portal V15.1, V16, V17 and V18 project with SIWAREX WP321 and SIWAREX DB – KTP700 Basic
  • TIA Portal V17 and V18 project with SIWAREX WP321 and SIWAREX DB - MTP 700 Unified Comfort

ATTENTION:
STEP 7 V17 Update 4 and Unified Panel Image and/or Unified Runtime V17 Update 4 is required to use the Project including the MTP 700 Unified Comfort Panel.


TIA Portal example project for S7-300 and S7-400 
(S7-315-2 PN/DP and TP700 Comfort or KTP700 Basic) in German, English, French, Spanish and Italian consisting of HMI visualization and WP321 function block (multiinstance ability). Please use / copy the function block included in the project for all other CPU of the 300 and 400 series as well.

The .zip-file includes the following components:

  • TIA Portal V15.1, V16, V17 and V18 project with SIWAREX WP321 – TP 700 Comfort
  • TIA Portal V15.1, V16, V17 and V18 project with SIWAREX WP321 and SIWAREX DB – KTP700 Basic

========================================================================================

Ready-for-use-small TIA Portal

TIA Portal example project (S7-1511 and KTP700 Basic) in German, English, French, Spanish and Italian consisting of HMI visualization and WP321 function block (multiinstance ability) with lower memory demand. This function block has the the data records 3, 6, 10 and 14 available only, which allow the commissioning of the scale, the definition of the limits, as well as the selection of the process values read by cyclic I/O communication.

All further data records, as well as the advanced error message system and the multiplexed commands 1, 2 and 3 are not available by this type of function block
!

The .zip-file includes the following components:

  • TIA Portal V13 SP1, V14, V15, V15.1, V16, V17 and V18 project with SIWAREX WP321 – KTP 700 Basic

 Login required  Download (36,6 MB)

========================================================================================

Library TIA Portal 

TIA Portal V13, V14, V15, V15.1, V16, V17 and V18 global block library with all available WP321 function blocks for S7-1200, S7-1500 and S7-Software Controller

ATTENTION: It’s important to choose the right project/library relating to the CPU firmware version!

 Login required  Download (24,4 MB) 

========================================================================================

Ready-for-use SIMATIC Manager

The S7-Classic project includes a ready-to-use project with a SIWAREX WP321 connected to a CPU 315-PN/DP and a HMI with WP321 function block (multiinstance ability). Please use / copy the function block included in the project for all other CPU of the 300 and 400 series as well.

The .zip-file includes the following components:

  • Simatic Manager V5.5 SP4 project with SIWAREX WP321 and KTP600 (WinCC flexible 2008 SP3)
  • Simatic Manager V5.6 SP2 project with SIWAREX WP321, SIWAREX DB and KTP 700 (TIA Portal V15.1)

  Download (3,4 MB)

========================================================================================

Ready-for-use-small SIMATIC Manager

The Simatic-Manager project-archive (SIMATIC Manager V5.5 SP4 is required) includes a ready-to-use project with a SIWAREX WP321 connected to a CPU 315-PN/DP and a HMI (KTP600 Basic) with WP321 function block (multiinstance ability) with lower memory demand. This function block provides access to the data records 3, 6, 10 and 14 only, which allow the commissioning of the scale, the definition of the limits, as well as the selection of the process values read by cyclic I/O communication.

All further data records, as well as the advanced error message system and the multiplexed commands 1, 2 and 3 are not available with this type of function block!

 Registrierung notwendig  Download (3,9 MB)

========================================================================================

TIA Portal example project to program several SIWAREX WP321 in one project.

The TIA Portal Project is based on the example project for S7-1500 in German and English, it has been developed in order to connect several scales to a 1500-CPU or 1200-CPU which is connected to a panel. This   document (2,2 MB) describes the procedure. 

The .zip-file includes the following components:

  • TIA Portal V15.1, V16, V17 and V18 project with SIWAREX WP321 – TP 700 Comfort

 Login required  Download (30,8 MB) 

========================================================================================

TIA portal library for Siwarex WP321 to limit the simultaneously use of system function data record read and / or write

The library is created for 1200 and 1500 CPU’s. The function block “WP321_Token” is an extension of the “WP321_Multiplex” getting started. This   document (568,9 KB) describes the procedure.

 Registrierung notwendig  Download (228,3 KB)

PLC Programming with SIMATIC STEP7

 

Innovative engineering for both proven and new SIMATIC controllers

SIMATIC STEP 7 (TIA Portal) continues the success story of SIMATIC STEP 7. With SIMATIC STEP 7 (TIA Portal), you can configure, program, test, and diagnose the Basic, Advanced and Distributed Controllers of all generations, whether PLC- or PC-based, including software controllers.

 STEP 7 (TIA Portal) helps you perform your engineering tasks intuitively and efficiently. Thanks to its integration in TIA Portal, STEP 7 offers transparency, intelligent user navigation, and straightforward workflows in every work and programming step. Functions such as drag & drop, copy & paste, and Auto Complete make work much quicker and easier.

 SIMATIC STEP 7 offers maximum user-friendliness, regardless of whether you‘re a beginner in the engineering field or already have many years of experience. For new users, the engineering is easy to learn and apply, whereas for experts, it’s fast and efficient.


SIMATIC STEP 7 in TIA Portal is the comprehensive engineering tool for configuring and programming SIMATIC controllers, whether PLC- or PC-based.

SIMATIC STEP 7 Professional (TIA Portal) can be used to configure, program, test, and diagnose all generations of SIMATIC controllers. 

SIMATIC STEP 7 Basic (TIA Portal) is the price-optimized subset of STEP 7 Professional software that can be used both for engineering the SIMATIC S7-1200 Basic Controllers and for configuring the SIMATIC HMI Basic Panels, because WinCC Basic is part of the software package.

 

  

Application-oriented licensing

Today’s automation solutions must overcome a variety of challenges. To do this, they require high-performance software that is as efficient, flexible, and reliable as possible, both now and in the future. By choosing the right license for your individual application, you’ll keep your software cost-effectively up to date.

 Download, please check this link: 

https://support.industry.siemens.com/cs/document/109772803/simatic-step-7-inkl-safety-und-wincc-v16-trial-download?dti=0&lc=de-WW

 

 

Saturday, November 12, 2016

Siemens TIA Portal

Divisi Industri Otomatisasi dari Siemens saat ini memperkenalkan Totally Integrated Automation Portal (TIA Portal) – software otomatisasi pertama dengan Engineering Environment dan Software project terpadu. Software ini memudahkan para penggunanya untuk melakukan pengembangan dan komisioning terhadap sistem otomatisasi secara cepat dan intuitif, yang memberikan efisiensi lebih terhadap waktu dan biaya yang diakibatkan oleh adanya berbagai macam software dalam melakukan integrasi. Didesain sedemikian rupa untuk efisiensi tinggi dan penggunaan yang mudah, TIA Portal telah disesuaikan untuk para pemula dan professional. Untuk selanjutnya TIA Portal ini merupakan dasar utama dari semua paket software engineering di kemudian hari untuk konfigurasi, pemrograman dan komisioning produk perangkat otomatisasi yang ada dalam portofolio produk Totally Integrated Automation dari Siemens. Sebagai contoh adalah New Simatic Step 7 V11 automation software untuk Simatic PLC dan Simatic WinCC V11 untuk Simatic HMI (Human machine Interface) dan aplikasi visualisasi.
Desain dari TIA Portal ini, Siemens telah mempelajari banyak aplikasi software engineering yang ada beberapa tahun ini serta mengamati dan melakukan evaluasi terhadap kebutuhan para penggunanya di seluruh dunia. Sebagai komponen dari perangkat engineering software Siemens, TIA Portal memberikan shared services yang lebih maju antar configuration interfaces yang menjamin keseragaman navigasi kepada para penggunanya serta sistem yang konsisten. Sebagai contoh, semua perangkat dan jaringan di dalam system automasi sekarang ini dapat dikonfigurasikan melalui satu perangkat dan editor jaringan. Project navigation, library concepts, data management, project storage, diagnostics dan online function merupakan layanan standard yang tersedia untuk para pengguna TIA Portal ini. Software development environment gabungan ini menawarkan tingkat efisiensi yang tinggi di seluruh project automation yang di dalamnya terdapat programmable controllers, HMI devices dan Drives. Sebagai tambahan, semua data management untuk parameter-parameter pada controller, block-block, tag-tag atau messages ini hanya memerlukan sekali input – sangat menghemat waktu dan biaya software engineering dari project itu sendiri. TIA Portal ini didesain berdasarkan advanced object-oriented software architecture serta data management yg terpusat, yang memberikan konsistensi data yang berkesinambungan secara otomatis untuk menghindari error pada data entry. Para pengguna dapat dengan mudah menemukan data yang diinginkan dan program blocks dari seluruh automation project menggunakan project-wide cross-reference system, yang dapat mengurangi waktu troubleshooting dan debugging program program project yang ada.
Aplikasi terpadu yang baru ini memungkinkan semua Programmable Controller Siemens, HMI operator panel dan drives dikonfigurasikan melalui satu environment development yang sama. Kelebihan ini dapat menurunkan biaya interfacing serta konfigurasi pada layanan-layanan yang biasa dilakukan ketika pengaturan komunikasi antar controllers, drives dan HMI devices. Sebagai contoh, pengguna hanya perlu melakukan drags and drops sebuah tag yang ada di dalam PLC, seperti sinyal dari modul I/O ke dalam tampilan HMI. Tag tersebut secara otomatis terbentuk di dalam HMI dan koneksi antara controller dengan HMI akan ter-create secara otomatis tanpa diperlukan konfigurasi manual.
Engineering software Simatic Step 7 V11 pada TIA Portal, dapat mendukung PLC Siemens seperti Simatic S7-1200 controllers, Simatic S7-300 dan Simatic S7 400 controllers serta PC-based automation system Simatic WinAC. Dengan cakupan programmable controllers yang luas memungkinkan Simatic S7 V11 untuk memenuhi tuntutan kinerja dan kemampuan yang menyeluruh dari sebuah software engineering untuk automation system. Kelebihannya adalah pemindahan konfigurasi yang ada di dalam Simatic Controllers dan HMI devices ke dalam project software baru hanya memerlukan waktu yang cukup singkat sehingga dapat menghemat waktu dan biaya untuk proses migrasi.
Simatic WinCC V11 yang baru ini juga berpatokan pada TIA Portal yang termasuk di antaranya konfigurasi machine-level application yg menggunakan HMI operator panels yang mendukung model panel Simatic TP dan MP, Simatic HMI Comfort Panel dan PC-based SCADA (Supervisory Control and Data Acquisition) process visualization system. Konfigurasi dan commissioning untuk Sinamics inverter drive nantinya juga akan dikembangkan di dalam TIA portal ini. (kpl/sie/roc)
#