Comparison of Soft Starting and Frequency Converter Motor Starting

Soft starting

A soft starter is, as you would expect, a device which ensures a soft starting of a motor.
A soft starter has different characteristics to the other starting methods. It has thyristors in the main circuit, and the motor voltage is regulated with a printed circuit board. The soft starter makes use of the fact that when the motor voltage is low during start, the starting current and starting torque is also low.
Motor soft starter
Motor soft starter

Advantages //

Soft starters are based on semiconductors. Via a power circuit and a control circuit, these semi-conductors reduce the initial motor voltage.
This results in lower motor torque.
During the starting process, the soft starter gradually increases the motor voltage, thereby allowing the motor to accelerate the load to rated speed without causing high torque or current peaks.
Soft-starting curve - Synchronous speed - Full load torque (left) and Full load current (right)
Soft-starting curve – Synchronous speed – Full load torque (left) and Full load current (right)

Soft starters can also be used to control how processes are stopped. Soft starters are less expensive than frequency converters.
Another feature of the soft starter is the soft stop function, which is very useful when stopping pumps where the problem is water hammering in the pipe system at direct stop as for star-delta starter and direct-on-line starter.

Drawbacks //

They do, however, share the same problem as frequency converters: they may inject harmonic currents into the system, and this can disrupt other processes. 
Voltage ramp for soft starter. Run-up time is around 1 sec.
Voltage ramp for soft starter. Run-up time is around 1 sec.

The starting method also supplies a reduced voltage to the motor during start-up.
The soft starter starts up the motor at reduced voltage, and the voltage is then ramped up to its full value. The voltage is reduced in the soft starter via phase angle. In connection with this starting method current pulses will not occur. Run-up time and locked-rotor current (starting current) can be set.

Electric Motor Soft Start 60HP (VIDEO)

Part 1


Part 2


Frequency converter starting

Frequency converters are designed for continuous feeding of motors, but they can also be used for start-up only.
The frequency converter is sometimes also called VSD (Variable Speed Drive), VFD (Variable Frequency Drive) or simply Drives, which is probably the most common name.
The drive consists primarily of two parts, one which converts AC (50 or 60 Hz) to DC and the second part which converts the DC back to AC, but now with a variable frequency of 0-250 Hz. As the speed of the motor depends on the frequency this makes it possible to control the speed of the motor by changing the output frequency from the drive and this is a big advantage if there is a need for speed regulation during a continuous run.
As stated above, in many applications a drive is still only used for starting and stopping the motor, despite the fact that there is no need for speed regulation during a normal run. Of course this will create a need for much more expensive starting equipment than necessary.
By controlling the frequency, the rated motor torque is available at a low speed and the starting current is low, between 0.5 and 1.0 times the rated motor current, maximum 1.5 x In.
Another available feature is softstop, which is very useful, for example when stopping pumps where the problem is water hammering in the pipe systems at direct stop. The softstop function is also useful when stopping conveyor belts from transporting fragile material that can be damaged when the belts stop too quickly.
It is very common to install a filter together with the drive in order to reduce the levels of emission and harmonics generated.
Frequency converter and its line diagram
Frequency converter and its line diagram

Advantages //

The frequency converter makes it possible to use low starting current because the motor can produce rated torque at rated current from zero to full speed. Frequency converters are becoming cheaper all the time.
As a result, they are increasingly being used in applications where soft starters would previously have been used.
Frequency converter curve – Synchronous speed – Full load torque (left) and Full load current (right)
Frequency converter curve – Synchronous speed – Full load torque (left) and Full load current (right)

Drawbacks //

Even so, frequency converters are still more expensive than soft starters in most cases; and like soft starters, they also inject harmonic currents into the network.

What is a drive? (VIDEO)


VLT drives in large desalination plant (VIDEO)


VLT drives control cooling tower fans (VIDEO)


References //

4 Steps To Follow During Commissioning of a PLC System

PLC programs are never final…

Yes, PLC programs are never final, it is always possible to make corrections and subsequent adaptations to new system according the customer requirements. Even during commissioning,program changes are often necessary. The commissioning of a system can be divided into four steps:
  1. Checking the hardware
  2. Transferring and testing the software
  3. Optimisation of the software
  4. Commissioning of the entire system

1. Checking the hardware

Each sensor, switch and button is connected to a specific input and each actuator to an output. During engineering process addresses and wires must not be mixed up. Also, the sensors and actuator placing should be checked (that they are where they have to be in the automated system).
During checking procedure, the outputs are set in a test mode. The actuators must then meet the specified requirements (functions). If changes are made, then the documentation (allocation list, drawings, etc) must also be updated to respond to reality.
PLC hardware
PLC hardware (photo credit: BR Automation)

1.1 Testing inputs and outputs

Input devices, e.g. switches, can be manipulated to give the open and closed contact conditions and the corresponding LED on the input module observed. It should be illuminated when the input is closed and not illuminated when it is open.
Failure of an LED to illuminate could be because the input device is not correctly operating, there are incorrect wiring connections to the input module, the input device is not correctly powered or the LED or input module is defective. For output devices that can be safely started, push buttons might have been installed so that each output can be tested.

2. Transferring and testing of software

Prior to commissioning, all available off-line and virtual PLC program testing tools should be used intensively to find program faults. For example, such test tool is in STEP 7 as subprogram S7-PLCSIM. It simulates the work of a PLC (virtual PLC) and allows the user written PLC program to be tested.
Following this, the program is transferred to a central processing unit in the virtual PLC. The entire program is executed without using the real PLC.
The user has to simulate the input signal changes and verify how the outputs react to it. Some PLCs offer simulation in a real PLC: the entire program is executed in a PLC without the real inputs and outputs being connected. Processing of the PLC outputs thus only takes place in the PLC image table. The physical PLC I/Os are not updated to/from the PLC I/O images.
Therefore this eliminates the risk of damaging machines or system parts.
After this, the individual user program parts and system functions are tested: manual operation, setting, individual monitoring programs etc. and finally the interaction of the program parts with the help of the main program.
The system can and should be commissioned step-by-step. Important aspects of commissioning and fault detection are the test functions of the programming system, such as the single-step mode or the setting of stop points. The single-step mode in particular is of importance, whereby theprogram in the PLC memory is executed line-by-line or step-by-step. In this way, any program faults which may occur in the program can be immediately localized.

3. Optimisation of the software

User programs can almost always be improved after the first test run. It is important that any corrections or modifications are made not just in the PLC user program, but are also taken into account in the documentation.

4. Commissioning of the entire system

This already occurs in part during the testing and optimization phase. Once the final status of thePLC user program and the documentation is established, all the controller functions (in accordance with the automation task) need to be executed step-by-step again.
If no faults occur by the entire system commissioning, then the system is ready to be handed over to the customer.
PLC panel during commissioning
PLC panel during commissioning (photo credit: megawatts.com.sg)

Saturday, December 10, 2011

How to become an Electrical Engineer ?

Electrical Control PanelElectrical Engineering is a very interesting field which you can choose for you education. My article : “How to become Automation and Control Engineer” was a very successful one, so today we’ll talk about electrical engineers.

Electrical Engineer Career – job description

Electrical engineers design, improve, develop and maintain electrical systems and its components to required specifications, focusing on economy, safety, reliability, quality and sustainability.
If you choose this role, you could work in a range of areas, including:
  • transport networks, including rail electrification and signalling
  • machine control systems and control panels
  • power generation, transmission and distribution
  • renewable energy sources, such as solar panelling, hydroelectric and wind turbines
  • manufacturing and construction
  • building services, such as lighting, heating, ventilation and lift systems.

Salary of Electrical Engineers in Europe

Income depends on experience and education:
  • Graduate engineers can earn between £20,000 and £25,000 a year.
  • Experienced engineers can earn between £28,000 and £38,000.
  • Chartered electrical engineers can earn between £40,000 and £50,000 a year.
  • Electrical managers between £ 45,000 and £ 70,000 a year.

Jobs and task in electrical engineer role ?

  • designing electrical systems and products;

  • reading design specifications and technical CAD drawings;

  • researching suitable solutions and estimating costs and timescales;

  • working to international, British (BS), European (EN) and other standards;

  • liaising with clients and contractors to discus projects; 

  • designing and conducting tests;

  • servicing and maintaining equipment;

  • preparing product documentation, writing reports and giving presentations;

  • monitoring a product in use to improve on future design.

  • perform detailed calculations to compute and establish manufacturing, construction, and installation standards and specifications.Inspect completed installations and observe operations, to ensure conformance to design and equipment specifications and compliance with operational and safety standards.

  • prepare specifications for purchase of materials and equipment.

  • prepare and study technical drawings, specifications of electrical systems, and topographical maps to ensure that installation and operations conform to standards and customer requirements.

  • plan layout of electric power generating plants and distribution lines and stations.
  • Thursday, May 12, 2011

    Electrical Design Software (Eplan)

    Buat para electrical Engineer, pasti anda bertanya" software apa yang biasa digunakan untuk membuat gambar listrik di Industri" besar? Jawabannya: banyak software yang bisa digunakan. Mungkin di Asia lebih terkenal orang menggunakan Autocad Electric, di eropa Eplan, X-Elec, dll. Berikut ini video yang menjelaskan kelebihan software Eplan.







    Untuk informasi lebih detail silahkan cek disitusnya:
    http://www.eplanusa.com/products/eplan-electric-p8/what-s-new.html 
    http://www.eplan-your-engineering.com/handbook

    EPLAN Electric P8 Reference Handbook, 2nd edition

    Written by an EPLAN user for EPLAN users, this 552-page handbook will put you well on your way to understanding the key concepts of the trailblazing EPLAN Electric P8 E-CAE software that's been setting standards in electrical design and documentation for more than 25 years. EPLAN Electric P8 Version 2.0 is straightforward, easy to use and contains many new innovations. The 2nd edition of this practical guide is equally clear cut and user friendly. The completely revised edition has been updated to cover the new Version 2.0 and includes a great deal of fresh material.
    The handbook starts with a detailed introduction to EPLAN Electric P8 and goes on to describe the system's many functions. Program-specific features are highlighted and tips for accomplishing general everyday tasks are presented. New chapters provide an in-depth explanation of the brand new EPLAN Pro Panel module (3D mounting layout) and the numerous features and improvements found in Version 2.0. There is also a brief introduction to master data, forms and plot frames as well as a chapter containing answers to FAQs.
    Other topics covered include: Creating projects // New features in the graphical editor // Using the various navigators // Device types and functions // Managing parts and messages // Revision control // Option technology // Macros with value setsPractical examples illustrate the many ways to use EPLAN Electric P8, providing readers with new methods of mastering day-to-day tasks.
    About the Author
    Bernd Gischel, graduate engineer, works for Dressel GmbH in Unna as an EPLAN administrator and designer of electrical engineering systems. Mr. Gischel has been designing with EPLAN since 1989 and is considered an expert level user of all EPLAN electrical design products including the previous versions EPLAN 5 and EPLAN 21. He moderates the corresponding EPLAN forum on www.cad.de as well as the "P8 Magic" knowledge portal in German about EPLAN Electric P8.

    Examples
    Register here to download the demo project referenced in the Handbook for Version EPLAN Electric P8 2.0 and EPLAN Education.
    Handbook Version 1.9

    Electrical Wire

    Bagaimana cara mengetahui kekuatan penghantar listrik (Kabel) lebih detail. Silahkan cek video dibawah ini.







    Electrical Wire Gauge Comparison Table

    This table is the comparison chart for both AWG and metric wire sizes, including the makeup and construction of electrical wire. You can compare AWG to SWG and metric square milimeter cable sizes with the equivalent circular MIL conductor sizes. 


    Circ. Mils Equivalent
    Circ. Mils
    Awg.
    Size
    Metric
    Wire
    Size
    mm2
    Stranding/ Wire
    Dia. per Strand
    Approximate
    Overall Diameter
    in mm in mm
    -
    1020
    -
    1620
    1620
    -
    -
    987
    -
    1480
    -
    -
    1974
    1974
    -
    20
    -
    18
    18
    -
    -
    0.50
    -
    0.75
    -
    -
    1.0
    1.0
    1/.032
    7/.0121
    1/.039
    1/.0403
    7/.0152
    1/.045
    7/.017
    1/.813
    7/.307
    1/.991
    1/1.02
    7/.386
    1/1.14
    7/.432
    .032
    .036
    .039
    .040
    .046
    .045
    .051
    0.81
    0.91
    0.99
    1.02
    1.16
    1.14
    1.30
    2580
    2580
    -
    -
    4110
    4110
    -
    -
    2960
    2960
    -
    -
    16
    16
    -
    -
    14
    14
    -
    -
    1.5
    1.5
    -
    -
    1/.0508
    7/.0192
    1/.055
    7/.021
    1/.0641
    7/.0242
    1/1.29
    7/.488
    1/1.40
    7/5.33
    1/1.63
    7/.615
    .051
    .058
    .055
    .063
    .064
    .073
    1.29
    1.46
    1.40
    1.60
    1.63
    1.84
    -
    -
    6530
    6530
    -
    -
    4934
    4934
    -
    -
    7894
    7894
    -
    -
    12
    12
    -
    -
    2.5
    2.5
    -
    -
    4
    4
    1/.071
    7/.027
    1/.0808
    7/.0305
    1/.089
    7/.034
    1/1.80
    7/.686
    1/2.05
    7/.775
    1/2.26
    7/.864
    .071
    .081
    .081
    .092
    .089
    .102
    1.80
    2.06
    2.05
    2.32
    2.26
    2.59
    10380
    10380
    -
    -
    13090
    13090
    -
    -
    11840
    11840
    -
    -
    10
    10
    -
    -
    9
    9
    -
    -
    6
    6
    -
    -
    1/.1019
    7/.0385
    1/.109
    7/.042
    1/.1144
    7/.0432
    1/2.59
    7/.978
    1/2.77
    7/1.07
    1/2.91
    7/1.10
    .102
    .116
    .109
    .126
    .1144
    .130
    2.59
    2.93
    2.77
    3.21
    2.91
    3.30
    16510
    16510
    -
    -
    20820
    20820
    -
    -
    19740
    19740
    -
    -
    8
    8
    -
    -
    7
    7
    -
    -
    10
    10
    -
    -
    1/.1285
    7/.0486
    1/.141
    7/.054
    1/.1443
    7/.0545
    1/3.26
    7/1.23
    1/3.58
    7/1.37
    1/3.67
    7/1.38
    .128
    .146
    .141
    .162
    .144
    .164
    3.26
    3.70
    3.58
    4.12
    3.67
    4.15
    26240
    26240
    -
    33090
    41740
    -
    -
    31580
    -
    -
    6
    6
    -
    5
    4
    -
    -
    16
    -
    -
    1/.162
    7/.0612
    7/.068
    7/.0688
    7/.0772
    1/4.11
    7/1.55
    7/1.73
    7/1.75
    7/1.96
    .162
    .184
    .204
    .206
    .232
    4.11
    4.66
    5.18
    5.24
    5.88
    -
    -
    52620
    66360
    -
    -
    49340
    49340
    -
    -
    69070
    69070
    -
    -
    3
    2
    -
    -
    25
    25
    -
    -
    35
    35
    7/.085
    19/.052
    7/.0867
    7/.0974
    7/.100
    19/.061
    7/2.16
    19/1.32
    7/2.20
    7/2.47
    7/2.54
    19/1.55
    .255
    .260
    .260
    .292
    .300
    .305
    6.48
    6.60
    6.61
    7.42
    7.62
    7.75
    Circ. Mils Equivalent
    Circ. Mils
    Awg.
    Size
    Metric
    Wire
    Size
    mm2
    Stranding/ Wire
    Dia. per Strand
    Approx.
    Overall Diameter
    in mm in mm
    83690
    -
    105600
    133100
    -
    167800
    167800
    -
    98680
    -
    -
    138100
    -
    -
    1
    -
    1/0
    2/0
    -
    3/0
    3/0
    -
    50
    -
    -
    70
    -
    -
    19/.0664
    19/.073
    19/.0745
    19/.0837
    19/.086
    19/.094
    37/.0673
    19/1.69
    19/1.85
    19/1.89
    19/2.13
    19/2.18
    19/2.39
    37/1.71
    .332
    .365
    .373
    .419
    .430
    .470
    .471
    9.43
    9.27
    9.46
    10.6
    10.9
    11.9
    12.0
    -
    -
    211600
    -
    250mcm
    300mcm
    187500
    187500
    -
    237.8mcm
    -
    -
    -
    -
    4/0
    -
    -
    -
    95
    95
    -
    120
    -
    150
    19/.101
    37/.072
    19/.1055
    37/.081
    37/.0822
    37/.090
    19/2.57
    37/1.83
    19/2.68
    37/2.06
    37/2.09
    37/2.29
    .505
    .504
    .528
    .567
    .575
    .630
    12.8
    12.8
    13.4
    14.4
    14.6
    16.0
    350mcm
    -
    400mcm
    -
    -
    500mcm
    500mcm
    -
    365.1mcm
    -
    473.6mcm
    473.6mcm
    -
    -
    -
    -
    -
    -
    -
    -
    -
    -
    185
    -
    240
    240
    -
    -
    37/.0973
    37/.100
    37/.104
    37/.114
    61/.089
    37/.1162
    61/.0905
    37/2.47
    37/2.54
    37/2.64
    37/2.90
    61/2.26
    37/2.95
    61/2.30
    .681
    .700
    .728
    .798
    .801
    .813
    .814
    17.3
    17.8
    18.5
    20.3
    20.3
    20.7
    20.7
    -
    600mcm
    700mcm
    750mcm
    750mcm
    -
    592.1mcm
    -
    -
    -
    -
    789.4mcm
    -
    -
    -
    -
    -
    300
    -
    -
    -
    -
    400
    61/.099
    61/.0992
    61/.1071
    61/.1109
    91/.0908
    61/.114
    61/2.51
    61/2.52
    61/2.72
    61/2.82
    91/2.31
    61/2.90
    .891
    .893
    .964
    .998
    .999
    1.026
    22.6
    22.7
    24.5
    25.4
    25.4
    26.1
    800mcm
    800mcm
    1000mcm
    1000mcm
    -
    -
    -
    986.8mcm
    -
    1233.7mcm
    -
    -
    -
    -
    -
    -
    -
    500
    -
    625
    61/.1145
    61/.0938
    61/.1280
    91/.1048
    91/.117
    61/2.91
    91/2.38
    61/3.25
    91/2.66
    91/2.97
    1.031
    1.032
    1.152
    1.153
    1.287
    26.2
    26.2
    29.3
    29.3
    32.7
    1250mcm
    1250mcm
    1500mcm
    1500mcm
    -
    -
    -
    -
    -
    1578.8mcm
    -
    -
    -
    -
    -
    -
    -
    -
    -
    800
    91/.1172
    127/.0992
    91/.1284
    127/.1087
    91/.132
    91/2.98
    127/2.52
    91/.1284
    127/.1087
    91/.132
    1.289
    1.290
    1.412
    1.413
    1.452
    32.7
    32.8
    35.9
    35.9
    36.9
    -
    2000mcm
    2000mcm
    1973.5mcm
    -
    -
    -
    -
    -
    1000
    -
    -
    91/.147
    127/.1255
    169/.1088
    91/3.73
    127/3.19
    169/2.76
    1.617
    1.632
    1.632
    41.1
    41.5
    41.5

    Remark:
    AWG:
    An electronics industry acronym for American Wire Gauge. AWG is a measure of the thickness of copper, aluminum and other wiring in the U.S. and elsewhere. Copper cabling typically varies from 18 to 26 AWG. The higher the number, the thinner the wire. The thicker the wire, the less susceptible it is to interference. AWG is known as BS (Brown & Sharp wire gauge). The AWG gauging system is defined as a geometrical progression because of the drawing mechanism nature. The 36 AWG is defined as 5 mil diameter, and the 4/0 AWG is defined as 460 mil diameter. In general, thin wire cannot carry the same amount of electrical current the same distance that thicker wire can. 


    MIL:
    A measurement of length or width; also of volume and angle. One mil is 0.001 inches length or width; in England, I am told that the term "thou" is 0.001 inch. Used frequently in measuring very large wire sizes. The circular mil is a unit of area used especially when denoting the cross-sectional size of a wire or cable. It is the equivalent area of a circle whose diameter is 0.001 (10-3) inch, or approximately 0.7854 millionths of a square inch (or 2.5 x 10-7 times pi). In plane geometry, area always varies in direct proportion to the square of the linear dimension. Thus, if wire A is twice the diameter of wire B, then wire A has four times the cross-sectional area, in circular mils, of B. If wire C is 1/5 of the diameter of wire D, then C has 1/25 the cross-sectional area, in circular mils, of D. In this respect, the circular mil is like any other unit for measurement of area. Because the circular mil is, as its name implies, based on a circular unit of measure rather than a rectangular unit, conversions between circular mils and square units such as the meter squared (m2) or centimeter squared (cm2) can be awkward. To convert circular mils approximately to meters squared (m2), multiply by 5.066 x 10-10. Conversely, multiply by 1.974 x 109. To convert circular mils approximately to centimeters squared (cm2), multiply by 5.066 x 10-6. Conversely, multiply by 1.974 x 105.

    As to volume, a metric unit of volume is equal to one thousandth of a liter. With respect to circular angular measurement, a mil (in military terms) is equal to 1/6400 of a complete revolution.


    Satu pertanyaan dari saya: Kenapa di Indonesia banyak kejadian kebakaran yang disebabkan oleh hubungan singkat (short circuit) arus listrik? .... Jawabannya: Salah satunya karena Ilmu listrik ini tidak digunakan. Sehingga kekuatan kabel tidak diperhitungkan dengan beban listrik yang terpasang. Kualitas kabel juga sangat mempengaruhi, jadi jangan sembarang menggunakan kabel listrik asal merek, kabel buat speaker dipakai buat listrik.. hal ini banyak terjadi di lingkungan kita. So, Gunakan ilmunya, Insya Allah pasti aman.

    Thursday, April 22, 2010

    Industrial Wire Management & Organized Wiring Systems

    Structured cabling in commercial buildings based on TIA/EIA standards has become a common practice in many building automation system applications. Panduit is promoting similar approaches for industrial automation. Jeff Paliga of Panduit answered the following questions about their approach.
     
    Why does Panduit think there is a wiring management need for industrial automation?
     
    The growing number of automation devices connected via Ethernet, is significantly complicating wire management requirements across a plant or facility, forcing manufacturers to change their approach to the planning, design, and installation of a network infrastructure.
     
    Without a good network management strategy in place, customers are at risk for unplanned downtime, inefficient maintenance, longer repair times, unreliable performance in harsh industrial applications, and loss of interoperability.
     
    How does Panduit specifically help customers improve network efficiency?
     
    Panduit Industrial Automation Solutions takes an integrated approach to the logical and physical network architecture, enabling organizations to bridge communication between factory floors and corporate offices. By integrating critical systems onto a single common infrastructure, Panduit Industrial Automation Solutions help customers improve network performance and operational efficiency, reduce operating costs, and increase productivity.
     
    Panduit offers a Reference Architecture Design Guide that shows customers how to properly plan, design, and install a network. One of the main topics within the guide is the use of Zone Topology, which optimizes the amount of wiring used for a network installation. The Reference Architecture Design Guide debuted at the Automation Fair 2009 in Anaheim and is available free by registering at www.panduit.com/IA
     
    Panduit’s Reference Architecture Design Guide
     
    How does Panduit specifically help reduce operational costs?
     
    Panduit solutions provide quick and dependable installations for greater reliability, availability, and security - and help improve mean time to repair (MTTR). Our solutions deliver measurable efficiency gains in the areas of space and power consumption across critical systems, contributing to sustainability and operational efficiency.
     
    How does Panduit address physical security?
     
    To help keep a network secure, Panduit takes a multi-layered approach to network physical security. For example, Panduit has “Lock-In, Block-Out, and Keyed” systems that are simple to install and deter unauthorized access of the physical layer.
     
    There seems to be a pattern to the colors of connectors, cables and other wiring management?
     
    Color-coding is a simple technique that is used within networks helping identify redundancy, VLAN, location and functionality. Panduit offers several products such as different colored communication cable, color-coded jacks and patch cord bands, and Tak-TyÒ Hook & Loop tape for ease of cable bundling and identification to help take the guess work out of troubleshooting, moving cables, adding cables and making changes. This also results in lower MTTR.
     
     
    Color Coding & Physical Network Security
     
    You also integrate fiber optic cables, how is it being accepted?
     
    In network designs, the use of optical fiber continues to grow due to performance, noise immunity and distance criteria. Fiber has been saddled with a perception that it is difficult to field-terminate [i.e. polishing and testing]. The Panduit OptiCam™ fiber system and tooling delivers superior performance parameters, eliminates the need for field polishing, and offers visual indication of proper termination to virtually eliminate operator error.
     
     
    OptiCam™ Fiber Termination Tool
     
    What specific problems does Panduit's wiring management solve?
     
    The Unified Physical Infrastructure℠ approach, or UPI, helps customers simplify networking, speed deployment, ensure harsh environment performance, and save valuable real estate on the manufacturing floor and critical infrastructure like control panels. For example, Panduit PanelMax™ DIN Rail Wiring Duct increases panel layout space and installs 40% faster than traditional methods. Another way we help our customers reduce risk is with a patching technique that allows easier terminations and pre-testing for verification of critical links. The resulting benefits are lower installed cost by reducing the number of rejected connectors and terminations since the Panduit optical fiber solution allows up to two re-terminations that provide yield rates approaching 100%.
     
    What types of system network cabling does UPI address?
     
    The UPI approach enables organizations to converge communication, computing, control, power, and security systems resulting in a number of benefits including lower life cycle cost, higher reliability and lower time to repair.
     
     
    Panduit UPI-based solutions for Industrial Automation offer a system that manages, connects and protects wire for electrical, control and networking applications. These solutions enable distributed control systems to be used across all manufacturing areas, providing a structured method of deploying physical infrastructure elements that will withstand harsh factory floor conditions while optimizing network performance and safety. Five targeted Industrial Solution Groups address a user’s needs from panel to plant:
     
    • IN-Panel: Control Panels, Electrical Panels, Specialty Panels and MCC (Motor Control Center)
    • IN-Room: Micro Data Center (Control Room area)
    • IN-Route: Network Distribution Pathways
    • IN-Field: Machine-mounted systems
    • IN-Frastructure: Industrial lighting, HVAC, security systems
     
    Can you provide some specific examples of new hardware to organize wiring beyond standard wire duct?
     
    Some new exciting products include the J-Pro™ Cable Support Systems which support open style routing of network cables. Inside a control panel, there are Fiber Slack Manager devices that maintain bend radius for fiber optic cables. And Dynamic Cable Tie Managers that provide strain relief for cables in area of movement (ie. on a control panel door).
     
     
    J-Pro Cable Support System
     
     
    Dynamic Cable Tie Manager
     
    What kind of results are users having with this approach?
     
    Customers have validated each level of our architecture concerning the value of the solution approach that addresses performance, security and maintainability. We have seen end users design control panels with 30% panel space savings, while ensuring performance with our noise mitigation solutions. Our fiber and copper solutions are being installed in zone architectures, leveraging Stratix™ Switches from Rockwell Automation to provide high performance, maintainable systems that minimize downtime. Our high quality termination solutions have helped customers with reliable connections throughout the physical infrastructure, and meeting standards including UL, CSA, IEEE Std 837-2002, and American Bureau of Shipping.
     
    What are plans for the future?
     
    Panduit is uniquely qualified to understand the complexities of plant-level networks, from monitoring production processes to optimizing pathway design. Panduit will continue to deliver UPI (Unified Physical Infrastructure) solutions for the manufacturing physical layer to efficiently manage converged networks for industrial applications.
     
    Panduit New World Headquarters – opening April 2010
     
    Our customers and our channel are looking for faster ways to deploy the network infrastructure. We are constantly working to deliver unique and optimized systems that provide measurable value to our customers and partners.
     
    Our new World Headquarters building, located in Tinley Park, IL, is a “living lab” demonstrating the UPI vision, in which critical power, communication, computing, security and control systems align contributing to our sustainability goals through a lower carbon footprint and energy savings of up to 20%. Through continued application research and collaboration with fellow industry leaders, we will enable customers to achieve greater ROI and meet their sustainability goals.
     
    More Information: www.panduit.com; email: cs@panduit.com

    Wednesday, September 30, 2009

    Basic Electrical Installation Book

    Basic Electrical Installation


    PDF | 9MB
    Download

    Electrical Engineering Know it all


    2008 / PDF / 7MB
    Download
    Reblog this post [with Zemanta]

    Thursday, March 19, 2009

    What is continuity test?

    Salah satu tahapan terpenting sebelum melakukan comissioining mesin yaitu continuity test. Lebih lengkap silahkan baca artikel ini.


    What is continuity?

    You might be asking, "What is continuity?" But don't worry, it's quite simple! Continuity means, are two things electrically connected. So if two electronic parts are connected with a wire, they are continuous. If they are connected with cotton string, they are not: while they are connected, the cotton string is not conductive.

    You can always use a resistance-tester (ohmmeter) to figure out if something is connected because the resistance of wires is very small, less than 100 ohms, usually. However, continuity testers usually have a piezo buzzer which beeps. This makes them very useful when you want to poke at a circuit and need to focus on where the probes are instead of staring at the meter display.

    For some basic circuits you can just look to see where the wires go to determine continuity but it's always wise to use a multimeter. Sometimes wires break or you're tired and can't easily follow all the PCB traces. I use continuity check all the time!

    What is it good for?

    Continuity is one of the most important tests. Here are some things it is good for

    • Determine if your soldering is good. If your solder joint it is a cold solder connection it will appear connected but in actually it is not! This can be really frustrating if you are not experienced in visually detecting cold solder joints
    • Determine if a wire is broken in the middle. Power cords and headphone cables are notorious for breaking inside the shielding, it appears as if the cable is fine but inside the wires have been bent so much they eventually broke.
    • Making sure something isn't connected. Sometimes a solder joint will short two connections. Or maybe your PCB has mistakes on it and some traces were shorted by accident.
    • Reverse-engineering or verifying a design back to a schematic
    Remember!

    You can only test continuity when the device you're testing is not powered. Continuity works by poking a little voltage into the circuit and seeing how much current flows, its perfectly safe for your device but if its powered there is already voltage in the circuit, and you will get incorrect readings

    Always test to make sure your meter is working before starting the test by brushing the two tips together, and verifying you hear the beep. Maybe the battery is low or its not in the right mode.

    Continuity is non-directional, you can switch probes and it will be the same.

    If you are testing two points in a circuit and there is a (big) capacitor between those points you may hear a quick beep and then quiet. That's because the voltage the meter is applying to the circuit is charging up the capacitor and during that time the meter 'thinks' its continuous (essentially)

    Small resistors (under 100 ohms or so) and also all inductors will seem like short circuits to a multimeter because they are very much like wires.

    Likewise, continuity doesn't mean "short" it just means very very low resistance. For example, if you have a circuit that draws an Amp from a 5V supply, it will appear to be a 5Ω resistor. If you measure that with your meter it will think its a short circuit, but really its just a high-drain circuit.

    Get into the mode

    First step is to get your multimeter into the correct mode. Look for the icon that looks sort of like a 'sound wave'

    Here are three examples. Note that sometimes the mode is "dual" (or possibly more) usage,





    Turn the multimeter knob so that it points to this symbol

    Touch and go

    For a majority of multimeters, you're ready to go, just touch the tips of the probes together so that they make a beeping sound!

    Here's a video demonstration

    If you can't view embedded videos, click here to download an mp4

    Here are some examples covering a couple of different multimeters

    Example 1

    This meter is very simple. When the probes are not touching, the display shows "1"

    When you touch the tips together, the display changes to a three digit mode (it's displaying resistance, which we will cover later) It also emits a beep

    Example 2

    This meter is dual-mode but still very easy to use. Turn the dial to the symbol. When the probes are not touching the display shows "OL" which stands for Open Loop. (Open loop is another way of saying there is no continuity)

    When you touch the probes, the soundwave icon shows up in the display (upper right) and it also shows a number. The number is not the resistance, actually...its the voltage (look for the V in the right hand side for Volts). This is because this mode is also a Diode Test (which will be discussed later)

    Example 3

    This meter is triple-mode and requires an extra step to get to the continuity function. Click on the image to get a closer view of the triple-mode. After you dial to this mode you must press the Mode button, the wave icon will then appear in the display.

    You can see the wave icon in the top right as expected. This meter also displays OL (I've noticed that nicer meters do this)

    Unlike the other meter, this one displays Ohms (see the symbol on the right of the display). The resistance is low (4.7Ohms) but not 0 (the ideal value) because the probes and wires act as resistors. Usually with these sorts of meters they will beep whenever resistance is under 100 ohms or so.

    Probing a PCB
    Here is an example of testing a PCB for continuity.The first test shows that the two points are not connected.

    The second test shows that these two points are connected

    #